Platinum RTD Probe Only

This product is covered by ACI's Five (5) Year Limited Warranty. Learn more

Product overview

100 Ohm (Two Wires) RTD, Probe Only, 4", 6' Plenum Cable

Application

  • Roof Top Units
  • Supply/Discharge Air/Return/Mixed/Exhaust Air Duct Temperature Sensing
  • Immersion Temperature Sensors
  • Replacement Temperature Sensors

Product specifications

Sensor Type | Sensor Curve:
Platinum RTD | PTC (Positive Temperature Coefficient)
Number Sensing Points:
One
Number Wires:
A/100-2W-PO-XX” Series and A/1K-2W-PO-XX Series: Two (Non-Polarity Sensitive) A/1K-2W-PO-XX” Series and A/1K-3W-PO-XX Series: Three (Polarity Sensitive)
Sensor Output @ 0ºC (32ºF):
A/100-xW-PO Series: 100 Ohms nominal | A/1K-xW-PO Series: 1000 Ohms nominal
Sensor Accuracy:
+/- 0.06% Class A (Tolerance Formula: +/- ºC = (0.15ºC + (0.002 * |t|)) where |t| is the absolute value of Temperature above or below 0ºC in ºC) -40ºC (-40ºF): +/- 0.23ºC (+/- 0.414ºF) | 0ºC (32ºF): +/- 0.15ºC (+/- 0.27ºF) | 200ºC (392ºF): +/- 0.55ºC (+/- 0.99ºF)
Din Standard | Temperature Coeffcient:
DIN EN 60751 (IEC 751) | 3850 ppm / ºC
Stability:
+/- 0.03% after 1000 Hours @ 300ºC (572ºF)
Response Time (63% Step Change):
8 Seconds nominal
Self-Heating | Maximum Operating Current:
100 Ohm RTD: 7 mW/ºC (Still Air) | 5 mA | 1K Ohm RTD: 4mW/ºC (Still Air) | 3 mA
Operating Temperature Range:
-40 to 200ºC (-40 to 392ºF)
Storage Temperature Range:
-40 to 85ºC (-40 to 185ºF)
Operating RH Range:
10 to 95% RH, non-condensing
Probe Material:
304 Stainless Steel
Standard Wire:
Lead Wire Insulation | Wire Rating:
Etched Teflon (PTFE) Colored Leads | MIL-W-16878/4 (Type E)
Operating Temperature Range:
-55°C (-67°F) to 200°C (392°F)
Conductor Material:
Silver Plated Copper
Rated Application:
Suitable for Indoor and Outdoor (wet) location. Oil, Moisture, Acids, Oils and Moisture Resistant
Lead Length | Conductor Size:
4”, 6” and 8” Probes: 14” (35.6 cm) | 12” and 18” Probes: 24” (61cm) | 22 AWG (0.65mm)
Plenum Wire:
Lead Wire Insulation | Wire Rating:
CL2P: FEP (Fluorinated Ethylene Propylene) | TYPE CL2P - TYPE CMP 22 AWG (UL), C(UL) FEP/FEP E130356 ROHS
Cable Operating Temperature Range:
CL2P: -80°C (-112°F) to 150°C (302°F)
Conductor Material:
CL2P: Tinned Copper
Rated Application:
CL2P: Suitable for Indoor and Outdoor (wet) locations. Oil, Gas, Sunlight, Abrasion Acid Resistant
Probe Material:
0.250" (6.35mm)
Product Weight:
4" = 0.028 lbs. (12.7g) 6" = 0.036 lbs. (16.3g) 8" = 0.044 lbs. (20g) 12" = 0.066 lbs. (29.9g) 18" = 0.09 lbs. (40.8g)
Agency Approvals:
CE, RoHS2, WEEE